Meanwell HDR-60-12 55W 12V DC Industrial DIN Rail Power Supply
AC-DC Ultra slim DIN rail power supply; Input range 85-264VAC; Output 12VDC at 4.5A; Pass LPS
(edit with the Customer Reassurance module)
(edit with the Customer Reassurance module)
(edit with the Customer Reassurance module)
HDR-60-12
55W 12V DC Industrial DIN Rail Power Supply
Product Description :
-
Ultra slim design 52.5mm (3SU) width
-
Universal input 85~264VAC (277VAC operational)
-
No load power consumption < 0.3W
-
Isolation class
-
Pass Limited Power Source (LPS)
-
Adjustable DC output voltage
-
Short Circuit, Over Load, Over Voltage Protection
-
Cooling by free air convection
-
Operating Temperature -30~70C
-
DIN Rail TS-35/7.5 or 15 mountable
-
Over Voltage category III
-
Power On LED Indicator
Specifications :
MODEL |
HDR-60-12 |
||
OUTPUT |
DC VOLTAGE |
12V |
|
RATED CURRENT |
4.5A |
||
CURRENT RANGE |
0 ~ 4.5A |
||
RATED POWER |
54W |
||
RIPPLE & NOISE (max.) Note.2 |
120mVp-p |
||
VOLTAGE ADJ. RANGE |
10.8 ~ 13.8V |
||
VOLTAGE TOLERANCE Note.3 |
±1.0% |
||
LINE REGULATION |
±1.0% |
||
LOAD REGULATION |
±1.0% |
||
SETUP, RISE TIME |
500ms, 50ms/230VAC 500ms, 50ms/115VAC at full load |
||
HOLD UP TIME (Typ.) |
30ms/230VAC 12ms/115VAC at full load |
||
INPUT |
VOLTAGE RANGE |
85 ~ 264VAC (277VAC operational ) 120 ~ 370VDC (390VDC operational ) |
|
FREQUENCY RANGE |
47 ~ 63Hz |
||
EFFICIENCY (Typ.) |
88% |
||
AC CURRENT (Typ.) |
1.2A/115VAC 0.8A/230VAC |
||
INRUSH CURRENT (Typ.) |
COLD START 30A/115VAC 60A/230VAC |
||
PROTECTION |
OVERLOAD |
105 ~ 160% rated output power |
|
Hiccup mode when output voltage <50%, recovers automatically after fault condition is removed Constant current limiting within 50% ~100% rated output voltage, recovers automatically after fault condition is removed |
|||
OVER VOLTAGE |
14.2 ~ 16.2V |
||
Protection type : Shut down o/p voltage, re-power on to recover |
|||
ENVIRONMENT |
WORKING TEMP. |
-30 ~ +70℃ (Refer to "Derating Curve") |
|
WORKING HUMIDITY |
20 ~ 90% RH non-condensing |
||
STORAGE TEMP., HUMIDITY |
-40 ~ +85℃, 10 ~ 95% RH non-condensing |
||
TEMP. COEFFICIENT |
±0.03%/℃ (0 ~ 50℃) RH non-condensing |
||
VIBRATION |
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6 |
||
OPERATING ALTITUDE |
2000 meters |
||
OVER VOLTAGE CATEGORY |
Ⅲ;According to EN61558, EN50178,EN60664-1, EN62477-1;altitude up to 2000 meters |
||
SAFETY & EMC (Note 4) |
SAFETY STANDARDS |
UL62368-1, UL508, TUV EN61558-2-16, IEC62368-1, EAC TP TC 004, BSMI CNS14336-1 approved; Design refer to TUV EN62368-1 |
|
WITHSTAND VOLTAGE |
I/P-O/P:4KVAC |
||
ISOLATION RESISTANCE |
I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH |
||
EMC EMISSION |
Parameter |
Standard |
|
Conducted |
EN55032(CISPR32), CNS13438 |
||
Radiated |
EN55032(CISPR32), CNS13438 |
||
Harmonic Current |
EN61000-3-2 |
||
Voltage Flicker |
EN61000-3-3 |
||
EMC IMMUNITY |
EN55024, EN55035, EN61000-6-2, EN61204-3 |
||
Parameter |
Standard |
||
ESD |
EN61000-4-2 |
||
Radiated Susceptibility |
EN61000-4-3 |
||
EFT/Burest |
EN61000-4-4 |
||
Surge |
EN61000-4-5 |
||
Conducted |
EN61000-4-6 |
||
Magnetic Field |
EN61000-4-8 |
||
Voltage Dips and interruptions |
EN61000-4-11 |
||
OTHERS |
MTBF |
927.6K hrs min. MIL-HDBK-217F (25℃) |
|
DIMENSION |
52.5*90*54.5mm (W*H*D) |